ILF 1000 Inline Filter

Authorised UK Distributor

SKU: 503-661

MPN: 1UA1030307

At a glance

What it is
A BOFA inline filter unit (ILF 1000).
Best for
Processes that generate a lot of dust: it sits ahead of the extractor and extends the life of the extractor's own filters.
Key facts
650 x 617 x 763mm.

Description

The BOFA ILF 1000 is the ideal companion for BOFA fume extraction systems, particularly in applications where high levels of dust and particulate are generated.


Positioned alongside the main filtration unit, it enhances the overall filter capacity, extending the life of the primary filters and improving extraction efficiency.

The innovative DeepPleat DUO pre-filter features a 15-litre drop-out chamber and an F8 media layer with over 30 square metres of surface area, providing superior filtration performance. This robust unit ensures long-lasting performance in challenging environments.

 

Compatible Filter:


Features

  • High Dust Capacity: Designed for use in applications with heavy dust and particulate generation.
  • Extended Filter Life: Increases the lifespan of the main filters by boosting filter capacity.
  • DeepPleat DUO Pre-Filter: Features a 15-litre drop-out chamber and a sealed 200mm deep pleat layer of F8 media.
  • Large Surface Area: The pre-filter offers over 30 square metres of filtration surface for maximum efficiency.
  • Durable Construction: Constructed with stainless steel for durability and reliability.
  • Dimensions: 650 x 617 x 763mm, offering a compact yet efficient design.
  • Weight: 25kg for stable and secure installation.
  • Exhaust Outlet: 125mm for effective airflow.
  • Compatible Filter: Works with the DeepPleat DUO Pre-Filter (A1030222).

Download datasheets

SKU: 503-661

Prices Ex. VAT

BUY 3+ SAVE 5%

Stock SKU 1-2 3+ Qty Total
0 503-661 £1,196.94
Ex. VAT
£1,137.09
Ex. VAT
£0.00
Ex. VAT
Choose the quantity in the table
Your total shows here as you go.
0 IN STOCK

If stock level is 0 or not shown, you can still ORDER ONLINE and we will advise you by email when your back-ordered item/s will be delivered.

LEV Testing

SEE HERE for details of how we can help with LEV (Local Exhaust Ventilation) testing.

Frequently asked questions

Which BOFA extractor do I need for hand soldering?

For irons with tip extraction, the T15 serves up to 15 operators. For arms over the bench, the V200 covers one operator and the V250 two. Larger lines use the V600, V Oracle iQ or V 1000 iQ.

What is the difference between tip extraction and arm extraction?

Tip extraction draws fume through a tube on the iron, millimetres from the joint. Arm extraction uses a flexible arm and nozzle over the work. Both capture at source, which COSHH requires; a window does not.

How often should I change BOFA filters?

There is no set interval, because life depends on what and how much you extract. Change the pre-filter when the filter indicator calls for it and the combined HEPA/gas filter when the indicator or iQ display reports it. A fresh pre-filter protects the main filter.

What is a combined HEPA/gas filter?

One cartridge with two stages: a pleated glass-fibre HEPA section removing 99.97% of particles at 0.3 microns, and a treated activated-carbon section that absorbs gases and vapours. Laser and FumeCAB 1000 iQ versions reach 99.997%.

What is a DeepPleat DUO pre-filter?

BOFA's high-capacity pre-filter, with a large pleated media area that captures the bulk of particulate before the main filter, extending its life and keeping airflow up.

Which BOFA unit is right for a laser engraver?

Light use: AD Access or AD 350. Light to medium industrial: AD Nano. Industrial: AD Oracle iQ or SA iQ. Heavy duty: AD 500, 1000, 1500 or 2000 iQ. For a desktop laser the AD Base 1 or 2 doubles as the workstation.

Can I laser-cut PVC with a normal extractor?

No. PVC produces corrosive fume. BOFA's AD PVC iQ has coated internal surfaces and HCl and VOC sensors for exactly this job.

What does iQ mean on a BOFA unit?

BOFA's Intelligent Operating System: real-time performance information for the operator, downloadable data for evaluation, accurate filter alerts and, on larger units, airflow held steady as filters fill.

Are BOFA extractors noisy?

They are built for the bench. The T15 and V600 have built-in silencing, and the AD Oracle SA iQ is rated at 60 dBA. Noise figures are on each product page.

Does Grove Sales do LEV testing?

Yes. We provide LEV examination and testing on all BOFA equipment to keep your extraction compliant with COSHH, which requires testing at least every 14 months.

Is Grove Sales an authorised Donaldson BOFA distributor?

Yes. We stock the full range, including genuine replacement filters and spares, from our base in Christchurch, Dorset.

What arm sizes and ends are available?

ESD stay-put arms in 32, 50 and 75 mm, unit-mounted or bench-bracket, 1 m or 1.4 m, with nozzle, funnel, slot or plenum ends and an LED-lit option.